The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A new and simple method for fabricating controllable insulated nanometer-sized platinum electrodes is presented. Electrochemical etching of platinum wire is employed, and then a repeated process of cycle voltammetric deposition of electrophoretic paint and heat curing for shrink film follows which effectively controls the size of the nanoelectrodes, which is different from previous DC electrolysis...
Multiwalled carbon nanotubes, a new nanoscale material, has been gained many interests for use in various fields, and has exhibited exceptional merit as SPE absorbents for enrichment of environmental pollutants. This paper focused on the enriching power of atrazine and simazine, two important widely used triazine herbicides and described a novel and sensitive method for determination of these two...
A headspace single-drop microextraction (SDME) method has been developed in combination with electrothermal atomic absorption spectrometry for determination of total inorganic Se and Se(IV). SeH 2 is generated in a 40mL volume closed-vial and trapped onto a Pd(II)-aqueous containing drop that is supported at the needle tip of a high-precision chromatographic syringe. Sample pre-treatment by...
Molecular recognition sites for mercury ions were imprinted in TiO 2 film using stable ground-state complex of 1-amino-8-naphtol-3,6-disodium sulfonate (ANDS) and mercury ions as template. The complex ratio between mercury ions and ANDS was estimated to be 2:1. Compared with the controlled and pure TiO 2 electrodes, the imprinted electrode revealed selectivity towards the imprinted...
A reagentless amperometric uric acid biosensor based on zinc sulfide (ZnS) quantum dots (QDs) was firstly developed. It could detect uric acid without the presence of an electron mediator. The carboxyl group functionalized ZnS QDs were synthesized, and they were soluble biocompatible and conductive. ZnS QDs conjugates could provide increased enzyme binding sites, which may result in higher enzyme...
The polyamines, octyl-[2-(2-octylamino-ethylamino)-ethyl]-amine (L 1 ) and octyl-{2-[2-(2-octylamino-ethylamino)-ethylamino]-ethyl}-amine (L 2 ), have been used as anion ionophores in PVC-based membrane ion-selective electrodes. Different electrodes were prepared containing L 1 , or L 2 , and o-nitrophenyl octyl ether (NPOE) or bis(2-ethylhexyl)sebacate (DOS) as plasticizers...
A high performance liquid chromatography (HPLC) method has been developed for the simultaneous determination of four fluoroquinolones. The studied compounds have been enoxacin (ENO), norfloxacin (NOR), ofloxacin (OFLO) and enrofloxacin (ENRO). An isocratic elution method, using a mixture of tetrahydrofuran (8%) and phosphate buffer (pH 3.00, 30.0mM, 92%) as mobile phase, has been developed. Fluorimetric...
We developed a capillary electrophoretic system incorporating an ultra-violet absorption (UV)/chemiluminescence (CL) dual detector, taking advantage of the CL reaction of luminol-hydrogen peroxide and the batch-type CL detection cell. UV detection was carried out using the on-capillary method while CL detection was performed using the end-capillary method. Examination of isoluminol isothiocyanate...
A mediator-free amperometric biosensor for screening organophosphorus pesticides (OPs) in flow-injection analysis (FIA) system based on anticholinesterase activity of OPs to immobilized acetylcholinesterase enzyme (AChE) has been developed. The enzyme biosensor is prepared by entrapping AChE in Al 2 O 3 sol–gel matrix screen-printed on an integrated 3-electrode plastic chip. This strategy...
A selective removal of humic constituents involved in ester groups was conducted by a boron trifluoride–methanol transesterification reaction after removal of structurally unbound lipids. An analytical separation of subfractions containing specific classes of compound liberated from the humic matrix simplifies their identification by gas chromatography–mass spectrometry. We compared the traditional...
A simple and sensitive method has been developed for the analysis of residue amounts of chloroacetic acids in betaine samples based on derivatization by 1-naphthylamine (NA). The derivatized compounds are analyzed by reverse phase high performance liquid chromatography using methanol and water as mobile phase in the ratio of 32/68 (v/v) and phenyl column and PDA detection at 222nm. The detection limits...
The electrochemical analysis of tetracyclines was investigated using nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) by cyclic voltammetry and high performance liquid chromatographic with amperometry. Cyclic voltammetry was used to study the electrochemical oxidation of tetracyclines. Comparison experiments were carried out utilizing as-deposited BDD and glassy carbon electrodes...
A new efficient, simple and versatile algorithm is presented for determination of the protolytic constants from spectrophotmetric data in multiwavelength mode based on the combining of hard and soft modeling. The algorithm was checked by determining the acidity constants of a triprotic acid from theoretical and real absorption–pH data. The real spectral data are obtained from photometric titration...
The high sensitivity that can be attained using an enzymatic system and mediated by catechols has been verified by on-line interfacing of a rotating biosensor and continuous flow/stopped-flow/continuous-flow processing. Horseradish peroxidase, HRP, [EC 1.11.1.7], immobilized on a rotating disk, in presence of hydrogen peroxide catalyzed the oxidation of catechols, whose back electrochemical reduction...
Net analyte signal (NAS)-based multivariate calibration methods were employed for simultaneous determination of anthazoline and naphazoline. The NAS vectors calculated from the absorbance data of the drugs mixture were used as input for classical least squares (CLS), principal component and partial least squares regression PCR and PLS methods. A wavelength selection strategy was used to find the best...
A method for the determination of mercury via UV photoreduction has been investigated. Mercury vapor was generated by the reduction of mercury species in an acetic acid solution using UV radiation. Detection of the volatile mercury was accomplished by atomic absorption spectrometry. An optimized system was found to provide a detection limit (defined as the concentration giving a signal equal to three...
Atomic fluorescence spectrometry was used as an element-specific detector in hybridation with liquid chromatography (LC) and hydride generation for the speciation of Sb(III), Sb(V) and trimethylantimony dichloride (TMSbCl 2 ). The three species were poorly resolved in a single chromatogram but good results were obtained by anion-exchange chromatography, using a mobile phase with 20mM EDTA...
This article presents the validation results of a chiral liquid chromatographic (LC) method previously developed for the quantitative determination of R-timolol in S-timolol maleate samples. A novel validation strategy based on the accuracy profiles was used to select the most appropriate regression model, to assess the method accuracy within well defined acceptance limits and to determine the limits...
The Schlieren effect is a consequence of light inflexions altering the spectrophotometric measurements that are due to the formation of optical artefacts such as mirror and lenses inside the flowing sample. It may influence signal-to-noise ratio, sample throughput and measurement repeatability in spectrophotometric flow-based procedures. It was critically examined, in order to provide guidelines for...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.